Van Den Wymelenberg, K., & Inanici, M. (2014). A Critical Investigation of Common Lighting Design Metrics for Predicting Human Visual Comfort in Offices with Daylight. Leukos, 10(3), 145–164. https://doi.org/10.1080/15502724.2014.881720
Abstract
Existing visual comfort metrics are reviewed and critiqued based upon their ability to explain the variability in human subjective responses in a daylit private office laboratory environment. Participants (n = 48) evaluated visual comfort and preference factors, totaling 1488 discreet appraisals, and luminance-based metrics were captured with high dynamic range images and illuminance-based metrics were recorded. Vertical illuminance outperformed all commonly referenced visual comfort metrics including horizontal illuminance, IES luminance ratios, daylight glare probability (DGP), and daylight glare index (DGI). The bounded borderline between comfort and discomfort is introduced, and preliminary visual comfort design criteria are proposed for several existing metrics. Fundamental limitations of glare indices are documented, and the implications of inconsistent application of luminance ratio calculation methods are quantified. Future research is detailed.
Keywords
daylight glare; daylight metrics; luminance ratio; vertical illuminance; visual comfort